Instruments & automation · Sensors
Conductivity and resistivity sensors
- INDION TCI/K=0.01
- INDION TCI/K=0.1
- INDION TCI/K=1
- INDION TCI/K=10
- INDION TCI/K=0.01 resistivity sensor
- INDION DM 001
- INDION DM 01
- INDION DM 1

Product range
| Model | Types | Range | Leaflet |
|---|---|---|---|
| INDION TCI/K=0.01 | Flow Type | 0-20µs/cm | Download leaflet |
| INDION TCI/K=0.1 | Flow Type | 0-200µs/cm | Download leaflet |
| INDION TCI/K=1 | Flow Type | 0-2000µs/cm | Download leaflet |
| INDION TCI/K=10 | Flow Type | 0-20ms/cm | Download leaflet |
| INDION TCI/K=0.01 resistivity sensor | Flow Type | 0-20MΩ/cm | Download leaflet |
| INDION DM 001 | Flow Type | 0-20µs/cm | Download leaflet |
| INDION DM 01 | Flow Type | 0-200µs/cm | Download leaflet |
| INDION DM 1 | Flow Type | 0-2000µs/cm | Download leaflet |
INDION TCI/K=0.01
The new INDION TCI/K=0.01 Sensor Conductivity SS 316L Body, Teflon insulator, K=0.01 Co axial cell with Built in PT 100 or 1000, 5 Mtrs cable with pp flow Assy for D.M Water of 1-20μS.

- Sensor connection
Black wire for conductivity sensing
Shield wire for conductivity reference
Red and white wires for temperature.
INDION TCI/K=0.1
The new INDION TCI/K=0.1 Sensor Conductivity SS 316L Body, Teflon insulator, K=0.1 Co axial cell with Built in PT 100 or 1000, 5 Mtrs cable with pp flow Assy for D.M Water of 1-200μS.

- Sensor connection
Black wire for conductivity sensing
Shield wire for conductivity reference
Red and white wires for temperature.
INDION TCI/K=1
The new INDION TCI/K=1 Sensor Conductivity SS 316L Body, Teflon insulator, K=1 Co axial cell with Built in PT 100 / 1000, 5 Mtrs cable with pp flow Assy for D.M Water of 1-2000μS.

- Sensor connection
Black wire for conductivity sensing
Shield wire for conductivity reference
Red and white wires for temperature.
INDION TCI/K=10
The new INDION TCI/K=10 Sensor Conductivity SS 316L Body, Teflon insulator, K=10 Co axial cell with Built in PT 100 or 1000, 5 Mtrs cable with pp flow Assy for D.M Water of 1-20mS.

- Sensor connection
Black wire for conductivity sensing
Shield wire for conductivity reference
Red and white wires for temperature.
INDION TCI/K=0.01 resistivity sensor
The new INDION TCI Conductivity Sensor is used to to satisfy a broad range of applications in drinking water, ground water, food, etc.
The cell constant is a critical parameter affecting the conductance value produced by the cell and handled by the electronic circuitry.
In order to produce a measuring signal acceptable to the meter, it is highly important that the user chooses a cell constant appropriate for the sample. The technical specification table shows the optimum conductivity range of cells with different cell constants.

INDION DM 001
The new INDION DM Conductivity Sensor is used to satisfy a broad range of applications like drinking water, ground water, food, etc.
The cell constant is a critical parameter affecting the conductance value produced by the cell and handled by the electronic circuitry.
In order to produce a measuring signal acceptable to the meter, it is highly important that the user chooses a cell constant appropriate for the sample. The technical specification table shows the optimum conductivity range of cells with different cell constants.

INDION DM 01
The new INDION DM Conductivity Sensor is used to satisfy a broad range of applications like drinking water, ground water, food, etc.
The cell constant is a critical parameter affecting the conductance value produced by the cell and handled by the electronic circuitry.
In order to produce a measuring signal acceptable to the meter, it is highly important that the user chooses a cell constant appropriate for the sample. The technical specification table shows the optimum conductivity range of cells with different cell constants.

INDION DM 1
The new INDION DM Conductivity Sensor is used to satisfy a broad range of applications like drinking water, ground water, food, etc.
The cell constant is a critical parameter affecting the conductance value produced by the cell and handled by the electronic circuitry.
In order to produce a measuring signal acceptable to the meter, it is highly important that the user chooses a cell constant appropriate for the sample. The technical specification table shows the optimum conductivity range of cells with different cell constants.

Connect with our water treatment experts
Have a project or technical requirement to discuss? Connect with our team for expert guidance and tailored water treatment solutions.